PT5400
Pressure transmitter
PT-400-SEG14-A-ZVG/US/ /W
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PT5400-01 — 07.09.2015
Accuracy / deviations
Repeatability [% of the span]
< ± 0,05; (with temperature fluctuations < 10 K)
Characteristics deviation
[% of the span]
< ± 0,5; (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis)
Linearity deviation
[% of the span]
< ± 0,1 (BFSL) / < ± 0,2 (LS)
Hysteresis deviation
[% of the span]
< ± 0,2
Long-term stability
[% of the span]
< ± 0,1; (per 6 months)
Temperature coefficient zero
point and span
[% of the span / 10 K]
< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)
Response times
Step response time analogue
output
[ms]
1
Operating conditions
Ambient temperature [°C]
-40...90
Storage temperature [°C]
-40...100
Protection
IP 67; IP 69K
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years]
686
Pressure Equipment Directive
Sound Engineering Practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]
59
Materials
1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI
Materials (wetted parts)
1.4542 (17-4 PH / 630)
Min. pressure cycles
60 million; (at 1.2 times nominal pressure)
Tightening torque [Nm]
25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating)
Process connection
threaded connection G 1/4 external thread (DIN EN ISO 1179-2)
Process connection sealing
FKM (to DIN 3869)
Restrictor element integrated
no
Remarks
Remarks
BFSL = Best Fit Straight Line
LS = limit value setting
Pack quantity
1 pcs.
Electrical connection
Connector: 1 x M12